Pneumatic Troubleshooting MCQ Quiz Part 2 of 5 | 50 Questions

Pneumatic Troubleshooting MCQ Quiz — Part 2 of 5

Components — Compressors, FRL, Valves & Fittings | 50 Practice Questions (Q51–Q100 of 250) | For ITI Fitter, Electrician, Mechanical, Diploma Mechanical/Production and industrial maintenance trainees

Topic Focus: Components — Compressors, FRL, Valves & Fittings
Covers compressor types, the FRL (Filter-Regulator-Lubricator) unit and its correct order, directional control valve (DCV) port/position codes (3/2, 5/2, 5/3), solenoid/pilot/poppet valves, silencers, tubing/fittings, dryers and receivers.
This is Part 2 of a 5-part, 250-question Pneumatic Troubleshooting practice series covering real-world fault-diagnosis scenarios.

📚 Want the Complete Question Bank PDF?

Get the complete 150+ question Troubleshooting Question Bank PDF covering all trades, with clear answers, for offline practice. One-time price: ₹99.

🛒 Buy PDF – ₹99
Question Palette (tap any number to jump)
Source basis: Standard industrial pneumatics principles, component functions and troubleshooting methods as taught in ITI/Diploma curricula, with reference to recognised practice such as ISO 8573-1 (compressed air purity classes) and ISO 15552 (pneumatic cylinder standards) where applicable. Prepared for practice and skill-building purposes; always follow your equipment manufacturer's manual and workplace safety procedures.

About this practice set

This page is Part 2 of 5 in the Pneumatic Troubleshooting MCQ Quiz series. It contains 50 multiple-choice questions (Q51 to Q100 of the 250-question set) on Components — Compressors, FRL, Valves & Fittings. The questions are written for ITI, diploma and B.Tech trainees and for anyone preparing for a maintenance or fault-finding interview. Each question has four options; the quiz above checks your answer and shows an explanation, and the full answer key is printed below so you can also revise without running the quiz.

How to use this quiz

  1. Attempt the questions in one sitting without searching for answers.
  2. Read the explanation shown after each answer, even when you were right.
  3. Write down the questions you missed and the reason in your own words.
  4. Open the answer key below to revise those questions.
  5. Retake the quiz after a day or two and compare your score.

Sample of what is covered

  • Which type of compressor is most common for small workshop or ITI lab pneumatic supply due to its simplicity and low cost?
  • Why is the lubricator normally installed last (closest to the point of use) in an FRL assembly?
  • Compared to a 5/2 valve, a '5/3' directional control valve additionally provides:
  • What is a key practical risk of a double-solenoid (memory) valve if a PLC program loses track of its actual state, for example after a power interruption?
  • A check valve (non-return valve) in a pneumatic circuit allows:
  • What is the function of a pressure switch commonly fitted to an air receiver?
  • What does the pressure rating stamped on a pneumatic hose or fitting typically indicate?
  • A pressure gauge fitted after a regulator in an FRL unit is used primarily to:

Answer key with explanations (50 questions)

Q1. Which type of compressor is most common for small workshop or ITI lab pneumatic supply due to its simplicity and low cost?

A. Reciprocating (piston) compressor ✓ Correct answer

B. Centrifugal compressor

C. Axial flow compressor

D. Diaphragm vacuum pump

Explanation: Reciprocating piston compressors are simple, robust and inexpensive at low-to-medium capacity, making them the standard choice for small workshops.
Q2. A rotary screw compressor is generally preferred over a reciprocating compressor for continuous industrial duty because it:

A. Provides smoother, pulsation-free continuous air delivery with less vibration ✓ Correct answer

B. Cannot be oil-lubricated under any circumstances

C. Only operates intermittently, never continuously

D. Requires absolutely no maintenance ever

Explanation: The continuously rotating screw elements deliver air with far less pulsation and vibration than a reciprocating piston, suiting sustained industrial duty cycles.
Q3. In a single-stage reciprocating compressor, air is compressed:

A. In two separate cylinders sequentially with intercooling between them

B. By a rotating vane element only

C. In one compression step directly from intake pressure to final delivery pressure ✓ Correct answer

D. By a helical screw element only

Explanation: A single-stage compressor raises air pressure in one continuous compression stroke, unlike a two-stage unit which splits compression across two stages with intercooling.
Q4. The primary role of the filter element in an FRL unit is to:

A. Remove solid particulates and bulk moisture from the compressed air before it reaches downstream components ✓ Correct answer

B. Regulate the output pressure to a set value

C. Add a fine lubricating oil mist to the air

D. Silence the noise of the valve's exhaust

Explanation: The filter stage traps dust, rust and condensed water droplets so they do not damage regulators, valves and actuators further downstream.
Q5. The pressure regulator in an FRL unit primarily functions to:

A. Remove solid particulates from the air

B. Reduce and maintain a set, stable downstream pressure regardless of upstream fluctuations ✓ Correct answer

C. Add lubricating oil mist to the air stream

D. Store a reserve volume of compressed air

Explanation: A regulator throttles the higher, fluctuating supply pressure down to a steady, adjustable working pressure suited to the downstream equipment.
Q6. The correct installation order of components in an FRL unit, in the direction of air flow, is typically:

A. Lubricator, then Filter, then Regulator

B. Regulator, then Lubricator, then Filter

C. Filter, then Lubricator, then Regulator

D. Filter, then Regulator, then Lubricator ✓ Correct answer

Explanation: Air should be cleaned first, pressure-regulated second, and only then have oil mist added last, so the lubricant is not filtered out before reaching the point of use.
Q7. Why is the lubricator normally installed last (closest to the point of use) in an FRL assembly?

A. So that the oil mist it adds is not stripped out by the filter before reaching components that need lubrication ✓ Correct answer

B. Because it must physically regulate pressure last in the chain

C. Because it filters contaminants more effectively when placed last

D. Its position in the assembly has no real effect

Explanation: Placing the lubricator after the filter and regulator ensures the oil mist it injects travels directly to the tool or actuator instead of being captured by an upstream filter.
Q8. What is the primary function of an air receiver (storage tank) in a compressed air system?

A. To generate compressed air directly from atmospheric air

B. To store compressed air, dampen pressure pulsations, and allow condensate to settle out ✓ Correct answer

C. To filter particulates from the air only

D. To lubricate downstream tools directly

Explanation: The receiver acts as a buffer that smooths compressor pulsations, meets short demand peaks, and gives moisture time to condense and be drained off.
Q9. A '3/2' directional control valve designation means the valve has:

A. 3 ports and 2 switching positions ✓ Correct answer

B. 3 switching positions and 2 ports

C. 3 cylinders controlled by 2 valves

D. A 3 bar pressure rating with 2 seals

Explanation: Valve designations state ports first and positions second, so a 3/2 valve has three ports (supply, outlet, exhaust) and two possible spool positions.
Q10. A common application of a 3/2 directional control valve is to:

A. Control a single-acting cylinder ✓ Correct answer

B. Control a double-acting cylinder on both ports

C. Regulate downstream pressure only

D. Filter moisture from the air supply

Explanation: A single-acting cylinder only needs one working port supplied and exhausted, which is exactly what a 3/2 valve's three ports provide.
Q11. A '5/2' directional control valve designation means the valve has:

A. 5 switching positions and 2 ports

B. 5 ports and 2 switching positions ✓ Correct answer

C. A 5 bar rating with 2 seals

D. 5 cylinders controlled by 2 valves

Explanation: A 5/2 valve has five ports, typically one supply, two working ports and two exhausts, with two switching positions.
Q12. A 5/2 directional control valve is most commonly used to control:

A. A double-acting cylinder, directing air alternately to each of its two ports ✓ Correct answer

B. A single-acting cylinder only

C. Only vacuum generators

D. Only rotary encoders

Explanation: The two working ports of a 5/2 valve allow it to supply one side of a double-acting cylinder while exhausting the other, and reverse this on switching.
Q13. Compared to a 5/2 valve, a '5/3' directional control valve additionally provides:

A. A built-in flow control valve

B. A third, typically centre/neutral, switching position such as closed-centre or open-centre ✓ Correct answer

C. A built-in pressure regulator

D. Two extra exhaust silencers as standard

Explanation: The '3' in 5/3 indicates a third spool position, usually a neutral or mid position, in addition to the two working positions found on a 5/2 valve.
Q14. A 5/3 valve with a 'closed centre' configuration means that in its neutral (mid) position:

A. All ports are connected to exhaust, letting the cylinder float freely

B. Supply is connected to both cylinder ports simultaneously

C. All ports are blocked, trapping air in the cylinder to hold its position ✓ Correct answer

D. The valve spool cannot be actuated from neutral

Explanation: A closed-centre valve isolates the trapped air on both sides of the piston in its neutral position, which can help hold the cylinder roughly in place.
Q15. A 5/3 valve with an 'open centre' (exhaust centre) configuration in its neutral position:

A. Blocks all ports completely

B. Connects both cylinder ports to exhaust, allowing the piston to be pushed freely by external force ✓ Correct answer

C. Pressurizes both cylinder ports simultaneously

D. Locks the spool permanently in that position

Explanation: With both working ports vented to exhaust, an open-centre neutral position removes back-pressure from the cylinder, letting it be moved freely by an external force.
Q16. A solenoid-actuated directional control valve converts what type of input into a mechanical spool shift?

A. A mechanical roller or cam input only

B. A manual push-button input only

C. A pneumatic pilot signal only

D. An electrical signal energizing a coil that creates a magnetic field to move the spool or pilot ✓ Correct answer

Explanation: The solenoid coil generates a magnetic field when energized electrically, and this field pulls an armature that shifts the valve's spool or pilot element.
Q17. A 'single solenoid, spring-return' directional control valve returns to its default position when:

A. The solenoid is de-energized, and spring force pushes the spool back ✓ Correct answer

B. The solenoid remains continuously energized

C. Air pressure reaches zero, and only then

D. It never automatically returns on its own

Explanation: Removing electrical power to a single-solenoid valve lets the internal return spring push the spool back to its normal, de-energized position.
Q18. A 'double solenoid' (bistable/impulse) directional control valve differs from a single-solenoid spring-return valve in that it:

A. Requires continuous power on one solenoid to hold either position

B. Has no spring and retains its last switched position even after the signal is removed ✓ Correct answer

C. Has only one solenoid coil fitted

D. Cannot be used to control double-acting cylinders

Explanation: A bistable valve has no centering spring, so a brief pulse to one solenoid switches it and it stays there until the opposite solenoid is pulsed, useful for maintaining state without continuous signal.
Q19. What is a key practical risk of a double-solenoid (memory) valve if a PLC program loses track of its actual state, for example after a power interruption?

A. The valve automatically resets to a safe default state, just like a spring-return valve

B. The valve may remain in its last physical position, which may not match what the program assumes, causing unexpected actuator motion on restart ✓ Correct answer

C. It has no risk at all since it always centres itself

D. It simply cannot be wired to a PLC output

Explanation: Because a bistable valve holds its last position with no spring bias, a PLC that assumes a different starting state after a power loss can command motion the operator does not expect.
Q20. The purpose of a pneumatic silencer (muffler) fitted to a valve exhaust port is to:

A. Increase the pressure of exhausted air

B. Reduce the noise generated by rapidly expanding exhaust air ✓ Correct answer

C. Filter incoming supply air before it reaches the valve

D. Add lubrication to the exhausting air

Explanation: A silencer slows and diffuses the rapid expansion of exhaust air, significantly cutting the sharp noise that would otherwise occur at an open exhaust port.
Q21. A common drawback of using an undersized or clogged silencer on a valve exhaust port is:

A. Faster actuator exhaust stroke speed

B. Increased back-pressure that slows the actuator's exhaust stroke ✓ Correct answer

C. Reduced noise beyond what is normally expected

D. Increased supply-side pressure

Explanation: A restricted exhaust path creates back-pressure that resists the piston's motion on the exhausting side, slowing that stroke.
Q22. Push-in (push-to-connect) pneumatic fittings are popular for workshop assembly mainly because they:

A. Require soldering to make a secure joint

B. Allow quick, tool-free connection and disconnection of tubing ✓ Correct answer

C. Only work with rigid metal pipe

D. Cannot hold pressure above 1 bar

Explanation: Push-in fittings use an internal collet and O-ring to grip and seal tubing instantly on insertion, avoiding threading or soldering for routine assembly changes.
Q23. Polyurethane (PU) tubing is widely used in pneumatic systems mainly because it offers:

A. Higher pressure rating than steel pipe of the same size

B. Good flexibility combined with reasonable pressure and abrasion resistance ✓ Correct answer

C. No flexibility at all, suited only to rigid routing

D. Electrical conductivity for equipment grounding

Explanation: PU tubing bends easily around machine layouts while still withstanding typical pneumatic working pressures and general wear, which is why it dominates workshop tubing.
Q24. What does the numeric size marking on pneumatic tubing, such as '6x4 mm', typically represent?

A. Length multiplied by weight

B. Outer diameter by inner diameter of the tube ✓ Correct answer

C. Pressure rating by temperature rating

D. Two different manufacturer colour codes

Explanation: Pneumatic tubing is conventionally sized by outer diameter by inner diameter, which determines both fitting compatibility and flow capacity.
Q25. A check valve (non-return valve) in a pneumatic circuit allows:

A. Air flow in one direction only, blocking reverse flow ✓ Correct answer

B. Free flow in both directions equally

C. Flow only when it is energized electrically

D. Flow that is proportional to ambient temperature

Explanation: A check valve uses a spring-loaded disc or ball that seals against reverse flow, permitting air to pass in only one intended direction.
Q26. What is the main function of a shuttle valve (OR-logic element) in a pneumatic circuit?

A. It combines two inlet signals and blocks the outlet whenever either is present

B. It lets air pass from either of two inlet signals through to a common outlet, effectively selecting whichever signal is present ✓ Correct answer

C. It regulates the downstream pressure to a fixed value

D. It can only be actuated electrically, never pneumatically

Explanation: A shuttle valve internally shifts a small shuttle to connect whichever inlet has the higher pressure to the common outlet, implementing a pneumatic OR function.
Q27. A quick-exhaust valve fitted close to a cylinder port is used to:

A. Slow down the cylinder's motion deliberately

B. Vent the cylinder's exhaust air rapidly and directly to atmosphere, bypassing the long return path through the main valve, increasing stroke speed ✓ Correct answer

C. Filter incoming supply air to the cylinder

D. Regulate the cylinder's supply pressure

Explanation: By venting locally rather than sending exhaust air all the way back through tubing and the main valve, a quick-exhaust valve significantly cuts exhaust restriction and speeds up that stroke.
Q28. Which valve actuation method uses a small physical lever or roller, commonly seen on limit-switch-style pneumatic valves?

A. Solenoid actuation

B. Mechanically (roller/cam) actuated valve ✓ Correct answer

C. Pilot air actuation

D. Manual push-button actuation

Explanation: A roller-lever valve is physically tripped when a moving machine part, such as a cam or cylinder rod, contacts and depresses its roller.
Q29. A 'pilot-operated' directional control valve shifts its main spool using:

A. Only electrical current applied directly to the spool

B. A small air signal acting on a piston or diaphragm to move the main spool, amplifying a low-power control signal ✓ Correct answer

C. Manual hand force applied to the spool alone

D. Gravity acting on the spool alone

Explanation: Pilot operation uses a small pneumatic signal to move a piston that in turn shifts a larger main spool, allowing a low-force signal to control a high-flow valve.
Q30. Why are pilot-operated solenoid valves commonly used for large-bore, high-flow directional control valves instead of direct-acting solenoid valves?

A. Direct-acting solenoids often lack the force to shift a large, high-flow spool, so a small pilot air signal is used to actuate the main valve ✓ Correct answer

B. Pilot valves are always cheaper regardless of the valve's size

C. Direct-acting solenoids cannot be wired to a PLC output

D. Pilot-operated valves need no air supply at all

Explanation: A solenoid's magnetic force is limited, so for large spools requiring more shifting force, the solenoid instead pilots a small internal valve that uses air pressure to move the main spool.
Q31. What is the function of a pressure switch commonly fitted to an air receiver?

A. It regulates the speed of a downstream cylinder

B. It automatically starts or stops the compressor motor based on tank pressure to maintain a set pressure band ✓ Correct answer

C. It filters particulates from stored air

D. It lubricates the compressor's internal parts

Explanation: A pressure switch monitors receiver pressure and switches the compressor motor on at a low set point and off at a high set point, maintaining pressure within a working band.
Q32. A normally closed 3/2 valve, when unactuated, has its outlet port:

A. Blocked, with the outlet connected to exhaust instead ✓ Correct answer

B. Fully pressurized from supply

C. Connected directly to a second cylinder

D. Permanently vented to a silencer regardless of actuation

Explanation: In the normally closed default state, supply is blocked from the outlet and the outlet is instead connected to exhaust, until the valve is actuated.
Q33. BSP (British Standard Pipe) thread is commonly used on pneumatic fittings in India primarily for:

A. Sealing threaded pipe connections to prevent air leakage ✓ Correct answer

B. Electrical grounding of the fitting

C. Structural mounting of the cylinder body

D. Filtering purposes within the fitting

Explanation: BSP threaded connections, sealed with tape or sealant, provide a reliable, leak-tight joint for compressed air piping and fittings.
Q34. What is the purpose of a moisture separator, often combined with the filter bowl, in an FRL unit?

A. To add moisture to the air for lubrication purposes

B. To remove bulk condensed water droplets from the compressed air stream before they reach downstream equipment ✓ Correct answer

C. To increase the air's pressure

D. To generate a vacuum signal

Explanation: A moisture separator uses a baffle or centrifugal action to spin out and collect free water droplets in the filter bowl, protecting downstream components.
Q35. A desiccant or refrigerant air dryer installed after the compressor primarily functions to:

A. Increase the compressed air system's pressure

B. Lower the dew point of compressed air, removing moisture that a simple filter cannot remove ✓ Correct answer

C. Reduce the noise generated by the compressor

D. Add lubricant to the compressed air

Explanation: Dryers actively remove water vapor (rather than just liquid droplets), lowering the pressure dew point far below what filtration alone can achieve.
Q36. Why is an automatic (float or electronic timer) drain preferred over a manual drain valve on modern air receivers and dryers?

A. It increases the system's working pressure

B. It replaces the need for any filtration in the system

C. It reliably removes accumulated condensate without relying on an operator remembering to drain manually ✓ Correct answer

D. It reduces the compressor's rated capacity

Explanation: Automatic drains discharge condensate on a schedule or when a float detects water, ensuring moisture is removed even if operators forget manual draining.
Q37. What does the pressure rating stamped on a pneumatic hose or fitting typically indicate?

A. Its maximum safe working pressure ✓ Correct answer

B. Its internal bore diameter

C. Its overall length

D. Its manufacturing date code only

Explanation: This rating states the highest pressure at which the hose or fitting is certified to operate safely, and it should never be exceeded in service.
Q38. A T-fitting (tee) in a pneumatic tubing layout is used to:

A. Split or combine air flow between three connection points ✓ Correct answer

B. Reduce the line's pressure

C. Filter contaminants from the air stream

D. Reverse the direction of air flow

Explanation: A tee fitting has three connection ports arranged so one line can branch into two, or two lines can merge into one.
Q39. A reducer or adapter fitting in a pneumatic line is used when:

A. Connecting tubing or pipe of two different diameters or thread sizes together ✓ Correct answer

B. Increasing the air receiver tank's capacity

C. Adding lubrication to the line

D. Reversing the direction of air flow

Explanation: Reducers bridge a size or thread mismatch between two components, allowing a leak-tight connection between different diameters or thread standards.
Q40. Oil-free (oil-less) air compressors are often specified for applications such as food processing or electronics assembly because they:

A. Always run quieter than any lubricated compressor

B. Eliminate the risk of oil carryover contaminating the product or sensitive components ✓ Correct answer

C. Require absolutely no maintenance

D. Cannot deliver high pressure air at all

Explanation: Oil-free compressors avoid introducing any lubricating oil into the compressed air, which matters where oil contamination would spoil food, electronics or coatings.
Q41. In a two-stage reciprocating compressor, the intercooler is positioned:

A. Between the low-pressure and high-pressure compression stages ✓ Correct answer

B. Only after the final delivery stage

C. Before the intake filter, upstream of compression

D. Inside the air receiver tank itself

Explanation: Intercooling occurs between stages, removing heat generated in the first stage before the partially compressed air enters the second, higher-pressure stage.
Q42. What is the function of an intake (suction) filter on an air compressor?

A. To prevent airborne dust and debris from entering the compressor cylinder and causing wear ✓ Correct answer

B. To regulate the compressor's output pressure

C. To silence the exhaust noise from downstream valves

D. To add lubrication to intake air

Explanation: The intake filter protects internal compressor components such as pistons, rings and valves from abrasive dust that would otherwise accelerate wear.
Q43. A pressure gauge fitted after a regulator in an FRL unit is used primarily to:

A. Allow the technician to visually verify and set the regulated downstream pressure ✓ Correct answer

B. Automatically increase downstream pressure

C. Filter contaminants from the air

D. Store a reserve of compressed air

Explanation: The gauge gives a direct visual readout of the pressure the regulator is currently delivering, letting a technician adjust the setting accurately.
Q44. What distinguishes a 'poppet' type valve construction from a 'spool' type valve construction in a directional control valve?

A. A poppet valve has no moving parts at all

B. A poppet valve seals with a disc or ball seating against an orifice, while a spool valve seals via a sliding cylindrical spool with lands ✓ Correct answer

C. A spool valve cannot handle high flow rates

D. There is no real functional difference between the two

Explanation: Poppet valves open and close by lifting a seating element off an orifice, while spool valves redirect flow by sliding a grooved cylindrical spool within a bore.
Q45. Compared to spool valves, poppet valves are often preferred for isolation applications because they:

A. Provide a tighter, more leak-free seal in the closed position ✓ Correct answer

B. Are always faster to switch under every condition

C. Require no seals of any kind

D. Cannot be actuated by a solenoid

Explanation: The direct seating action of a poppet against its orifice generally achieves a tighter shut-off than the small clearances inherent in a sliding spool design.
Q46. What is the main purpose of an air treatment 'combination unit' that integrates filter, regulator and sometimes lubricator into a single compact body?

A. To eliminate the need for a compressor entirely

B. To simplify installation and reduce pressure drop or leak points compared to separate components ✓ Correct answer

C. To increase system pressure beyond the supply pressure

D. To replace the function of the air receiver

Explanation: A combined FRL body needs fewer joints and less panel space than three separate housings, reducing potential leak points and simplifying piping.
Q47. A back-pressure regulator differs from a standard pressure-reducing regulator in that it:

A. Cannot be used anywhere in a pneumatic system

B. Maintains a set pressure upstream of itself by venting excess, rather than reducing pressure downstream ✓ Correct answer

C. Only ever filters particulates from the air

D. Always increases the downstream flow rate

Explanation: A back-pressure regulator holds upstream pressure at a set value by opening to relieve excess, the opposite function of a standard downstream pressure-reducing regulator.
Q48. What is a common cause of a pressure regulator failing to maintain a stable set pressure, with output pressure creeping upward over time?

A. A worn or damaged regulator seat or diaphragm allowing leakage past the closed valve seat ✓ Correct answer

B. Too much lubrication present in the line

C. Oversized downstream tubing being used

D. Excess silencer capacity fitted

Explanation: If the internal seat or diaphragm no longer seals fully, supply pressure can leak past it even when the regulator should be holding steady, causing output pressure to drift upward.
Q49. Why should compressed air tubing be routed away from sharp bends and hot surfaces, such as near a furnace?

A. It has essentially no effect on tubing performance

B. Sharp bends can kink and restrict flow, while heat can degrade plastic tubing material and cause failure ✓ Correct answer

C. It actually improves the distribution of lubrication

D. It reduces the switching time of nearby valves

Explanation: A kinked tube restricts or blocks airflow, and excessive heat softens or embrittles plastic tubing, both of which can lead to leaks, restricted flow, or tube failure.
Q50. What is the primary purpose of a manual shut-off (isolation) ball valve installed at the inlet of an FRL unit or machine?

A. To regulate downstream pressure precisely

B. To filter contaminants from the incoming air

C. To lubricate downstream components

D. To allow the local air supply to be isolated for maintenance or an emergency shutdown ✓ Correct answer

Explanation: A local isolation valve lets a technician cut off air supply to just that machine for safe servicing, without shutting down the entire plant's compressed air network.

Frequently asked questions

Who is this Pneumatic Troubleshooting quiz for?

It is for ITI, diploma and B.Tech students, apprentices and working technicians who want to test fault-finding knowledge. The explanations are written to teach the reason, not just the answer.

How should I use the answer key?

Attempt the quiz first without looking. Then open the answer key, read the explanation for every question you missed, and retake the part after a day to see whether the explanation stuck.

Do I need to finish all five parts?

No, but the parts build on one another: fundamentals first, then components, then circuits and real-world scenarios. Part 5 is the best test of whether you can apply the earlier parts to a live fault.